Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 9 de 9
1.
Ann Vasc Surg ; 104: 217-226, 2024 Mar 18.
Article En | MEDLINE | ID: mdl-38508445

BACKGROUND: To assess the mortality and outcomes after thoracic endovascular aortic repair (TEVAR) in patients with type B aortic dissection (TBAD) in mainland China, and to compare these outcomes with data from Western countries, while analyzing the potential reasons for differences among different countries. METHODS: An extensive literature search spanning from January 1999 to October 2023 was conducted using PubMed, Cochrane Library, and Embase databases for studies on endovascular treatment for TBAD. This systematic review and meta-analysis adhered to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. Data extraction and analysis followed the guidelines outlined in the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. Primary outcomes were in-hospital mortality and mid-term (< 5 years) mortality. RESULTS: Based on 25 publications (3,080 patients), pooled estimate for in-hospital mortality was 2.2% (95% confidence interval, 1.6%-2.9%). Major perioperative complications included stroke (2.4% [1.8%-3.3%]), spinal cord ischemia (1.4% [1.0%-2.2%]), retrograde type A aortic dissection (1.2% [0.8%-1.8%]), type I endoleak (5.6% [3.6%-8.6%]), visceral ischemia (1.0% [0.5%-2.1%]), and acute renal failure (2.8% [2.0%-3.8%]). Mid-term mortality was 5.1% (3.6%-7.3%), and secondary intervention rate was 4.9% (4.0%-6.0%) with 1.7% (1.0%-2.9%) conversion rate to open surgery. In subgroup analysis based on uncomplicated TBAD, in-hospital and mid-term mortality was 0.5% (0.2%-1.5%) and 0.6% (0.2-1.7%), respectively. Compared with data from Western countries, mainland Chinese patients had a lower mortality. CONCLUSIONS: In mainland China, the outcomes of endovascular treatment for TBAD are comparable to those of Western countries. The large number of patients undergoing TEVAR in mainland China and its good performance support the use of TEVAR in uncomplicated TBAD.

2.
J Endovasc Ther ; : 15266028231199930, 2023 Sep 20.
Article En | MEDLINE | ID: mdl-37728019

PURPOSE: To explore the role of location, length, and thickness of the intimal flap in the propagation of Stanford type B aortic dissection (TBAD) based on ex vivo porcine aorta models based on ex vivo porcine aorta models. MATERIALS AND METHODS: The porcine aortas were harvested and randomly divided into 6 groups to create various TBAD aortic models. We constructed intimal flaps for different locations (group A [entry tear on outer curvature] and group B [entry tear on inner curvature]), lengths (group C [long] and group D [short]), and thicknesses (group E [thick] and group F [thin]). For the ex vivo perfusion experiments conducted on model aortas, an experimental circulation loop (ECL) was employed. The pressure in false lumen (FL) was constantly monitored. A comparison was made between the morphological data collected before and after the experiment to quantify the changes in the FL after the experiment. RESULTS: Compared the results with group B, the mean peak pressures of the FL in group A were lower (106.87±15.55 vs. 124.01±22.75 mm Hg, p=0.028). The mean axial propagation length in group A was shown to be shorter than that of group B (88.14±33.38 vs. 197.43±41.65 mm, p<0.001). The mean peak pressure was higher in group C than in group D (144.04±19.37 vs. 92.51±26.70 mm Hg, p<0.001). The mean peak pressure of group E was higher than that of group F (160.83±32.83 vs. 109.33±15.62 mm Hg, p<0.001), as was the mean axial propagation length of group E (143.11±39.73 vs. 100.45±35.44 mm, p=0.021). According to the results of multivariable linear regression, axial propagation length=45.873-0.703×length of initial FL+0.863× peak pressure (p<0.001). CONCLUSION: There was a relationship between FL propagation and the location, length, and thickness of the intimal flap. The axial propagation length was related to the length of the intimal flap and the peak pressure of propagation. It may be helpful to evaluate the risk of propagation in patients with TBAD. CLINICAL IMPACT: This study found that the locations, lengths, and thickness of the intimal flap significantly contributed to propagation pressure of FL. Using dissection flap characteristics, a physician can predict FL development in a patient and formulate a treatment plan.The purpose was to investigate the relationship between the dissection flap characteristics (location, length, and thickness) and the propagation of the FL, which is not clear at present. This study employed porcine models to create an experimental circulation loop. The perfusion experiment was conducted using a FL without distal re-entry and a non-pulsating flow.

3.
Ann Vasc Surg ; 93: 122-127, 2023 Jul.
Article En | MEDLINE | ID: mdl-36870563

BACKGROUND: The aim of the study was to analyze the clinical characteristics of patients with Stanford type B aortic dissection (TBAD) and risk factors for poor prognosis after thoracic endovascular aortic repair (TEVAR). METHODS: Clinical records for patients with TBAD presenting to a medical center between March 1, 2012 and July 31, 2020 were reviewed. Clinical data including demographics, comorbidities, and postoperative complications were obtained from electronic medical records. Comparative analysis and subgroup analysis were performed. A logistic regression model was used to analyze prognostic factors in patients with TBAD after TEVAR. RESULTS: TEVAR was performed on all 170 patients with TBAD, and poor prognosis was identified in 28.2% (48/170) of cases. Patients with a poor prognosis were younger (38.5 [32.0, 53.8] years vs. 55.0 [48.0, 62.0] years, P < 0.001), had higher systolic blood pressure (SBP) (138.5 [127.8, 152.8] mm Hg vs. 132.0 [120.8, 145.3] mm Hg, P = 0.013) and more complicated aortic dissection patients (19 [60.4] vs. 71 [41.8], P = 0.029) than those without a poor prognosis. According to the results of binary logic regression analysis, the possibility of a poor prognosis after TEVAR decreased with each 10 years increase in age (odds ratio: 0.464, 95% confidence interval: 0.327-0.658, P < 0.001). CONCLUSIONS: There is an association between younger age and a poor prognosis after TEVAR in patients with TBAD, with the condition that those with poor prognoses have higher SBP and more complicated cases. In younger patients, postoperative follow-up should be more frequent, and complications should be managed in time.


Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Endovascular Aneurysm Repair , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/etiology , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/methods , Treatment Outcome , Endovascular Procedures/adverse effects , Endovascular Procedures/methods , Time Factors , Retrospective Studies , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Risk Factors
4.
Catheter Cardiovasc Interv ; 101(5): 907-910, 2023 04.
Article En | MEDLINE | ID: mdl-36906808

Patients with visceral artery aneurysms are rare, and the reported incidence of left gastric aneurysm (LGA) is only 4%. At present, although there is little knowledge about such disease, it is generally believed that appropriate treatment should be planned to prevent some dangerous aneurysms from rupturing. We introduced a case of 83-year-old patient with LGA who underwent endovascular aneurysm repair. The 6-month follow-up computed tomography angiography showed complete thrombosis in the aneurysm lumen. In addition, to insight the management strategy on LGAs deeply, a literature review concerning this entity published in recent 35 years was performed.


Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Embolization, Therapeutic , Endovascular Procedures , Humans , Aged, 80 and over , Gastric Artery/diagnostic imaging , Treatment Outcome , Embolization, Therapeutic/methods
5.
J Endovasc Ther ; 30(3): 441-448, 2023 06.
Article En | MEDLINE | ID: mdl-35249398

BACKGROUND: In this study, we aimed to evaluate hemodynamic influence of the dissected aortic system via various ex vivo type B aortic dissection (AD) models. METHODS: Twenty-four raw porcine aortas were harvested and randomly divided into 4 groups to create various aortic models. Model A was the control group, while models B to D indicated the AD group, where models B and C presented a proximal primary entry with the false lumen (FL) lengths of 15 and 20 cm, respectively, and model D presented a 20 cm FL with a proximal primary entry and a distal reentry. All the aortic models were connected to a mock circulation loop to attain the realistic flow and pressure status. The flow distribution rate (FDR) of the aortic branches was calculated. Doppler ultrasound was applied to visualize the AD structure and to attain the velocity of flow in both the true and false lumens. Several sections of the AD were stained with hematoxylin and eosin for histologic evaluation after the experiment. RESULTS: This study demonstrated that higher pressures were found for the AD group compared with the control group. The mean systolic pressures at the inlet of models A to D were 113.34±0.81, 120.58±0.52, 117.76±0.82, and 115.87±0.42 mm Hg, respectively. The FDRs of the celiac artery in models A to D were 8.65%, 8.32%±0.15%, 7.87%±0.13%, and 8.03%±0.21%, respectively. By ultrasound visualization, the velocity of the flow at the entry to the FL in the AD group ranged in 10 to 92 cm/s. The dissection flap presented pulsatile movement, especially in the models B and C which contained 1 primary entry without distal reentries. Histological examinations indicated that AD was located between the intimal and medial layers. CONCLUSIONS: Our ex vivo models demonstrated that the configuration of the dissected aorta influenced the pressure distribution. Moreover, the dissection flap affected the FDR of the aortic branches that possibly inducing malperfusion syndrome.


Aortic Aneurysm, Thoracic , Aortic Aneurysm , Aortic Dissection , Animals , Aorta/surgery , Aortic Aneurysm/pathology , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/pathology , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Hemodynamics , Swine , Treatment Outcome
6.
Front Cardiovasc Med ; 9: 869505, 2022.
Article En | MEDLINE | ID: mdl-35586645

Background: Endovascular repair of type B aortic dissection (TBAD) with aberrant right subclavian artery (ARSA) is challenging due to anatomical complexity. The embedded modular single-branched stent graft (EMSBSG) could solve this problem. However, the hemodynamic efficacy of this innovative technique has not been fully assessed. This study aimed to propose morphometric and functional indicators to quantify the outcomes of EMSBSG in treating TBAD with ARSA. Material and Methods: A patient who had TBAD with ARSA underwent EMSBSG implantation was admitted. Computational fluid dynamics (CFD) and three-dimensional structural analyses were conducted based on CTA datasets before the operation (Pre-1) and at 4 and 25 days after EMSBSG implantation (Post-1 and Post-2). Quantitative and qualitative functional analyses were conducted via pressure-, velocity- and wall shear stress (WSS) -based parameters, such as the luminal pressure difference (LPD), total energy loss, and flow distribution ratio. By precisely registering the aortas at the three time points, parameter variations in the EMSBSG region were also computed to investigate the prognostic improvement after EMSBSG implantation. Results: The first balance point of LPD distally shifted to the abdominal aorta in Post-1 by a distance of 20.172 cm, and shifted out of the dissected region in Post-2, indicating positive pressure recovery post EMSBSG. The flow distribution ratios of all aortic arch branches increased after EMSBSG implantation. A positive normal deformation index in the EMSBSG region confirmed true lumen expansion; dominant ARN (area ratio of negative value) of pressure and WSS-based parameters indicated an improved prognosis from Post-1 to Post-2. Conclusions: The short-term results of EMSBSG in treating TBAD with ARSA proved to be promising, especially in EMSBSG region. Comprehensive evaluation could provide new insight into the therapy of TBAD with ARSA. Thus, it might guide the further management of complex aortic arch lesions.

7.
Acta Biomater ; 146: 284-294, 2022 07 01.
Article En | MEDLINE | ID: mdl-35367380

AIMS: This study investigated the association between the macroscopic mechanical response of aortic dissection (AoD) flap, its fibre features, and patient physiological features and clinical presentations. METHODS: Uniaxial test was performed with tissue strips in both circumferential and longitudinal directions from 35 patients with (AoD:CC) and without (AoD:w/oCC) cerebral/coronary complications, and 19 patients with rheumatic or valve-related heart diseases (RH). A Bayesian inference framework was used to estimate the expectation of material constants (C1, D1, and D2) of the modified Mooney-Rivlin strain energy density function. Histological examination was used to visualise the elastin and collagen in the tissue strips and image processing was performed to quantify their area percentages, fibre misalignment and waviness. RESULTS: The elastin area percentage was negatively associated with age (p = 0.008), while collagen increased about 6% from age 40 to 70 (p = 0.03). Elastin fibre was less dispersed and wavier in old patients and no significant association was found between patient age and collagen fibre dispersion or waviness. Features of fibrous microstructures, either elastin or collagen, were comparable between AoD:CC and AoD:w/oCC group. Elastin and collagen area percentages were positively correlated with C1 and D2, respectively, while the elastin and collagen waviness were negatively correlated with C1 and D2, respectively. Elastin dispersion was negatively correlated to D2. Multivariate analysis showed that D2 was an effective parameter which could differentiate patient groups with different age and clinical presentations, as well as the direction of tissue strip. CONCLUSION: Fibre dispersion and waviness in the aortic dissection flap changed with patient age and clinical presentations, and these can be captured by the material constants in the strain energy density function. STATEMENT OF SIGNIFICANCE: Aortic dissection (AoD) is a severe cardiovascular disease. Understanding the mechanical property of intimal flap is essential for its risk evaluation. In this study, mechanical testing and histology examination were combined to quantify the relationship between mechanical presentations and microstructure features. A Bayesian inference framework was employed to estimate the expectation of the material constants in the modified Mooney-Rivlin constitutive equation. It was found that fibre dispersion and waviness in the AoD flap changed with patient age and clinical presentations, and these could be captured by the material constants. This study firstly demonstrated that the expectation of material constants can be used to characterise tissue microstructures and differentiate patients with different clinical presentations.


Aortic Dissection , Elastin , Adult , Aged , Bayes Theorem , Biomechanical Phenomena , Collagen/chemistry , Elastin/chemistry , Humans , Middle Aged , Stress, Mechanical
8.
Front Cardiovasc Med ; 9: 828910, 2022.
Article En | MEDLINE | ID: mdl-35449876

Background: Iliac branch devices (IBDs) are valid tools for internal iliac artery preservation during endovascular abdominal aortic aneurysm and iliac aneurysm repair. The purpose of this study was to evaluate the effectiveness of a novel IBD with an embedded branch configuration. Method: A typical iliac artery model was reconstructed, and two models were manufactured using three-dimensional printing technology. The novel IBD was deployed into one iliac artery model by an experienced vascular surgeon. A mock circulation loop (MCL) and a computational fluid dynamics (CFD) simulation were used to investigate the haemodynamic parameters of the iliac models without (Model A) and with (Model B) the IBD. A morphological analysis was conducted using computed tomography angiography and medical endoscopy. The flow distribution rate (FDR) and energy loss (EL) were used to quantify IBD performance. Results: The FDR of the right internal iliac artery in the MCL of Model A and Model B was 18.88 ± 0.12% and 16.26 ± 0.09%, respectively (P = 0.0013). The FDR of the right internal iliac artery in the CFD simulation of Model A and Model B was 17.52 and 14.49%, respectively. The EL of Model A was greater than Model B in both the MCL and the CFD simulation. Compared with Model A, Model B had a larger region (8.46 vs. 3.64%) with a relative residence time of >20 Pa-1 at peak systole. Meanwhile, the area where the oscillatory flow index was >0.4 was significantly smaller in Model B than in Model A (0.46 vs. 0.043%). The region with an average wall shear stress of >4 Pa was greater in Model B than in Model A (0 vs. 0.22%). Conclusion: The MCL and CFD simulation showed that the novel IBD had little impact on the FDR and EL of the iliac artery models. However, the IBD might be an effective tool for the treatment of abdominal aortic/iliac aneurysms that extend into branches. Further investigations are warranted to confirm whether this IBD could be useful in the clinic.

9.
Ann Vasc Surg ; 85: 371-382, 2022 Sep.
Article En | MEDLINE | ID: mdl-35339592

BACKGROUND: To provide a contemporary review on endovascular false lumen (FL) embolization for thoracic aortic dissection (AD) and evaluate its early outcome. METHODS: A systematic literature review on FL embolization for thoracic AD from January 2003 to December 2020 was performed under the instruction of Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. Each article was analyzed using a standardized protocol including predefined demographic characteristics, perioperative mortality, and major complications. RESULTS: A total of 29 papers with 229 patients were included into the analysis. The methods of FL occlusion used were the candy-plug technique, the knickerbocker technique, the "cork in the bottleneck" technique, and direct FL embolization with a combination of stent-grafts, coils, onyx, plugs, and glue. FL embolization procedure was performed in 79 patients (34.5%) with type A AD and 150 (65.5%) with type B AD. FL direct embolization was the most frequently used technique and it was applied in 198 (86.5%) patients. Candy-plug, knickerbocker, and "cork in the bottleneck" techniques were used in 26 (11.4%), 3 (1.3%), and 2 (0.9%) patients, respectively. Technical success was achieved in all patients except one (228/229, 99.6%) in which implantation of a stent to celiac trunk was not possible. There were 4 hospital deaths (1.7%). Neurological complications occurred in 6 patients (2.6%), including 4 (1.7%) spinal cord ischemia and 2 (0.9%) ischemic stroke. There were 1 (0.4%) iatrogenic retrograde dissection and 2 (0.9%) renal failure reported. The mean duration of follow-up was 16.5 months. There were 21 deaths (9.3%) during follow-up and 8 (3.6%) were aorta-related. Thirty three (14.7%) secondary interventions were performed. Five patients (2.2%) required an open completion thoracoabdominal procedure incorporating the stent-graft into the repair. Complete FL thrombosis was observed in 181 (80.4%) patients, 34 (15.1%) had partial thrombosis, and 10 (4.4%) had FL progression. CONCLUSIONS: FL embolization of the distal thoracic aorta is a promising technique in a group of patients to promote FL thrombosis and aortic remodeling in thoracic aorta.


Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Thrombosis , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Blood Vessel Prosthesis , Humans , Retrospective Studies , Stents , Thrombosis/surgery , Time Factors , Treatment Outcome
...